Cisco grounding requirements

WebOct 26, 2016 · One grounding lug that has two M6 bolt holes with 0.63 inch (5/8 inch) (1.60 cm) of spacing between them and a 6-AWG or larger multistrand copper cable. The grounding lug used can be either a 180-degree (straight) lug, as shown in Figure 3-3, or a 45-degree lug, as shown in Figure 3-4. Figure 3-3 180-Degree (Straight) Chassis … WebDec 2, 2003 · Cisco recommends to use the grounding holes on their equipment to connect a grounding lug. The nice thing is that these lugs are never in the box, according to Cisco 'the grounding lugs are not available from Cisco Systems; any electrical-connector vendor can provide this lug'.

Cisco Content Hub - Power and Cooling

WebMar 2, 2024 · Ground lug and screws (provided with the access point) Yes. Wall Mount Bracket. Yes. Four M6 x 12–mm Hex-head Bolts. Yes. Crimping tool for ground lug, Panduit CT-720 with CD-720-1 die No. Four wall mounting screws. No. Four wall anchors (specified for all material) No WebGuidelines and Best Practices for the Installation and ... - Cisco fnf background testing remake 2 https://twistedunicornllc.com

Physical and Logical Infrastructure Requirements - Cisco Press

WebFeb 12, 2024 · Attach the provided two hole ground lug to the chassis using M4x 8mm bolts and then to the central office (CO) or other interior ground system with number 6 AWG wire. The grounding connectors are on the right side of the chassis, and either one may be used. (See Figure 2-1.) Figure 2-1 Grounding Pad Locations (Catalyst 4849-10GE shown) … WebFeb 27, 2024 · Make sure that you follow grounding requirements, if any, at your site. Step 1 Use the ground lug screw and the lug ring for a single-hole ground connection. Use the dual-hole lug for a ground connection … green tomato mincemeat canning recipe

Cisco Content Hub - Power and Cooling

Category:Catalyst 3650 Switch Hardware Installation Guide

Tags:Cisco grounding requirements

Cisco grounding requirements

What equipment need grounding? - Cisco Community

WebAug 17, 2024 · Grounding cable (6 AWG recommended), sized according to local and national installation requirements; the required length depends on the proximity of the switch to proper grounding facilities Crimping tool large enough to accommodate the girth of the lug Wire-stripping tool Unpacking and Inspecting the Switch WebJun 24, 2024 · Grounding lug—A two-hole grounding lug, which supports a 6 AWG size wire. Supplied as part of the standard accessory kit. Grounding screws—Two M4 x 8 mm (metric) pan-head screws. …

Cisco grounding requirements

Did you know?

WebThis section describes the power and grounding requirements you must consider when planning the site facilities for the line card chassis. In addition, ... The Cisco CRS-1 line card chassis can be ordered with AC power shelves in either the Delta or Wye configuration. Each type of power shelf has a different Cisco part number to distinguish it ... WebMar 17, 2024 · Cisco Catalyst 9500 Series High Performance switch with optional network module 1 (power supply and fan modules not shown) 8. Two M4.0 x 20mm Phillips pan-head screws (Black color) 2 . Product documentation and compliance document. 9 . Ground lug and two M4.0 x 8mm Phillips pan-head screws. 3 . Two 19-inch mounting brackets

WebFeb 24, 2024 · Insert the stripped end of the grounding cable into the open end of the grounding lug. Step 3: Use the crimping tool to secure the grounding cable in the grounding lug. Step 4: Attach the ground … WebFeb 11, 2024 · General power and grounding requirements are: Installation of the Cisco CRS 16-Slot Line Card Chassis Enhanced router must follow national and local electrical codes: In the United States—United States National Fire Protection Association (NFPA) 70 and United States National Electrical Code (NEC)

WebJan 24, 2008 · For information on chassis grounding on Cisco 1700 series routers, see the hardware installation guide for your router. Cisco 2600 Series, Cisco 3600 Series, and Cisco 3700 Series Routers . The … WebFeb 11, 2024 · – AWG 18 (1 mm ) or larger wire for EN/IEC 60950-compliant chassis grounding For NEC-compliant grounding, an appropriate user-supplied ring terminal, with an inner diameter of 1/4 in. (5 to 7 mm) In addition, depending on the type of modules you plan to use, you might need the following equipment to connect a port to an external …

WebFeb 15, 2024 · Make sure to follow any grounding requirements at your site. Step 1 Use the ground lug screw and the lug ring for a single-ground connection. Use the dual-ground adaptor and dual-hole lug for a dual …

WebMar 13, 2024 · 1. Throughput measured with 1500B User Datagram Protocol (UDP) traffic measured under ideal test conditions. 2. “Multiprotocol” refers to a traffic profile consisting primarily of TCP-based … fnf backrooms mod onlineWebDec 2, 2003 · Cisco recommends to use the grounding holes on their equipment to connect a grounding lug. The nice thing is that these lugs are never in the box, … fnf background test 3WebApr 4, 2024 · Alternatively, you can ground the chassis by using a customer-supplied grounding cable that meets your local and national installation requirements. For U.S. installations, we recommend 6-AWG wire. Connect your grounding cable to the chassis with a grounding lug (provided in the switch accessory kit) and to the facility ground. Note green tomato mincemeat recipesWebMar 25, 2024 · For information on available PoE, PoE+, and Cisco UPOE/UPOE+ requirements, see these sections the Power Supply Modules. The 350 W and 715 W AC power supply modules are autoranging units that support input voltages from 100 through 240 VAC. ... Dual-hole ground lug and two screws (included in the DC power supply … fnf backrooms runWebNov 1, 2024 · 17.60 inches (44.70 cm) for the Cisco ASR 9910 Router. To mount the router in a 4-post rack, the usable aperture (the width between the inner edges of the two mounting flanges) must be at least 17.75 inches (45.09 cm) for the Cisco ASR 9922 Router or Cisco ASR 9912 Router. green tomato muffinsWebGeneral power and grounding requirements are: Installation of the routing system must follow national and local electrical codes: In the United States: United States … green tomato oradeaWebJan 26, 2024 · 2 Use a screwdriver to remove the port cover and access the port. 3 Use a screwdriver to remove the port cover and access the port. Ports. Note: Different configurations are available. Not all ports or slots are present in all configurations. 1G SFP/ 10G SFP+ Ports (Uplinks) fnf back rooms